MID 144-PPID 70 MID 144-PPID 70 MID 144 PPID 70 — OUTPUT SUPPLY #3 FMI 4 Voltage Below Normal, or Shorted To Low Source Failure Mode Identifier (FMI): 4 (Voltage Below Normal, or Shorted To Low Source) Conditions for fault code: Abnormally low voltage or short circuit to ground Parameter Identification (PPID): P70 Message Identification (MID): 144 Voltage below 3 volts Possible causes: Circuit Description: The Idle Validation Switch (IVS) updates the Vehicle Electronic Control Unit (VECU) with the idle status. At idle, the Idle Validation Switch (IVS) is open and no voltage is applied to the Idle Validation Switch (IVS) signal input.
At approximately 5% - 100% pedal position the Idle Validation Switch (IVS) closes. Faulty connector Faulty harness Supply voltage shorted low Reaction from Vehicle Electronic Control Unit (VECU): Location: The Idle Validation Switch is integral to the Accelerator Pedal Position (APP) Sensor. Yellow lamp is illuminated Normal Idle Validation Switch Parameters: The IVS should pass 12 volts through the switch when the throttle is off the idle position. Noticeable external symptoms: N/A Page 159 MID 144-PPID 70