MID 128-PID 108 MID 128-PID 108 MID 128 PID 108 — AMBIENT PRESSURE SENSOR FMI 3 Voltage Above Normal, or Shorted to High Source Failure Mode Identifier (FMI): 2 (Data Erratic, Intermittent or Incorrect), 3 (Voltage Above Normal, or Shorted To High Source), 4 (Voltage Below Normal, or Shorted To Low Source) Conditions for fault code: Short to battery on the metering side Parameter Identification (PID): P108 Possible causes: Internal fault in Engine Management System (EMS) Module Message Identification (MID): 128 Location: The Ambient Pressure Sensor is located inside the Engine Management System (EMS) Module. Faulty Ambient Pressure sensor Reaction from Engine Management System (EMS) Module:
MIL lamp illuminated The Ambient Pressure Sensor is shorted to another circuit. If the code is active, attempt to clear the code from memory and check if the code resets. If PID 108 resets, replace the Engine Management System (EMS) Module and retest the system. Pressure is set to default value FMI 4 Voltage Below Normal, or Shorted to Low Source Conditions for fault code: FMI 2 Short to ground on the metering side Data Erratic, Intermittent or Incorrect Possible causes: Internal fault in Engine Management System (EMS) Module Conditions for fault code: Ambient air pressure is showing too high or too low a value (abnormal value) Faulty Ambient Pressure sensor Possible causes:
Reaction from Engine Management System (EMS) Module: Faulty Ambient Pressure sensor MIL lamp illuminated Faulty Engine Management System (EMS) Module Pressure is set to default value Reaction from Engine Management System (EMS) Module: MIL lamp illuminated Noticeable external symptoms: Engine derate Black smoke (minor) Page 36 MID 128-PID 108