Mack Trucks V-MAC IV — Mack Trucks V-MAC IV — спецификация (EN)

MID 128-PSID 113 MID 128-PSID 113 MID 128 PSID 113 — THERMAL REGENERATION UNIT (TRU): SENSOR VOLTAGE SUPPLY Noticeable external symptoms: Aborted and ceased regeneration FMI 3 Failure Mode Identifier (FMI): 0 (Data Valid But Above Normal Operational Range - Most Severe Level), 1 (Data Valid But Below Normal Operational Range - Most Severe Level), 3 (Voltage Above Normal, or Shorted To High Source), 4 (Voltage Below Normal, or Shorted To Low Source) Voltage Above Normal, or Shorted To High Source Conditions for fault code: Sensor supply voltage is greater than 5.3 volts Parameter Identification (PSID): P113 Possible causes: Message Identification (MID):

128 Differential Pressure Sensor, harness, fittings and tubing FMI 0 Incorrect Differential Pressure Sensor voltage supply from Aftertreatment System Control Module Data Valid But Above Normal Operational Range - Most Severe Level Conditions for fault code: Faulty Aftertreatment System Control Module Sensor supply voltage is greater than 5.3 volts Reaction from Engine Management System (EMS) Module: Possible causes: Sensor signal shorted high MIL lamp illuminated Faulty Aftertreatment System Control Module Noticeable external symptoms: Reaction from Engine Management System (EMS) Module:

Aborted and ceased regeneration FMI 4 MIL lamp illuminated Voltage Below Normal, or Shorted To Low Source Noticeable external symptoms: Conditions for fault code: Aborted and ceased regeneration Sensor supply voltage is 0 volts FMI 1 Possible causes: Data Valid But Below Normal Operational Range - Most Severe Level Differential Pressure Sensor, harness, fittings and tubing Conditions for fault code: Incorrect Differential Pressure Sensor voltage supply from TRU Aftertreatment System Control Module Sensor supply voltage is less than 4.5 volts Possible causes:

Faulty Aftertreatment System Control Module Sensor signal shorted low Faulty Aftertreatment System Control Module Reaction from Engine Management System (EMS) Module: MIL lamp illuminated Reaction from Engine Management System (EMS) Module: Noticeable external symptoms: MIL lamp illuminated Aborted and ceased regeneration Page 84 MID 128-PSID 113