MID 128-PSID 114 MID 128-PSID 114 MID 128 PSID 114 — DIESEL PARTICULATE FILTER (DPF) SWITCH FMI 12 Bad Intelligent Device or Component Failure Mode Identifier (FMI): 9 (Abnormal Update Rate), 12 (Bad Intelligent Device or Component) Conditions for fault code: Switch will transmit "Start Regen" and "Inhibit" status Illegal operation Parameter Identification (PSID): P114 Possible causes: Message Identification (MID): 128 Bad device FMI 9 Reaction from Engine Management System (EMS) Module: Abnormal Update Rate Conditions for fault code: MIL lamp illuminated Missing signal Noticeable external symptoms: CM1 signal missing from Mack DPF smartswitch Regeneration not possible Possible causes:
Faulty harness Faulty connector Reaction from Engine Management System (EMS) Module: MIL lamp illuminated Noticeable external symptoms: Regeneration not possible Page 85 MID 128-PSID 114