4. PUTTING THE TRACTOR INTO SERVICE 4.3 RENEWAL OF THE TRANSMISSION CONTROL UNIT 8 - At the end of the calibration procedure, a message will appear confirming calibration successfully completed; at this point, exit the EDS program. 4.3.3 CALIBRATION OF THE MAIN CLUTCH PROPORTIONAL SOLENOID VALVE NOTE To carry out the calibration of the main clutch, warm the transmission oil to about 40 °C and position the tractor on a flat tarmac surface with at least 20 metres of free space ahead. Put the transmission in neutral by positioning the shuttle lever at “NEUTRAL”, and make certain the handbrake is released.
1 - Connect a portable computer with the EDS program installed (for details see «Connection of a portable computer with “EDS” software to the transmission control unit»). 2 - Turn the starter key to the (ON) position and start the EDS program. 3 - From the introductory menu, start the transmission diagnosis program by pressing key “1” and selecting option “2”. 20-29