4. PUTTING THE TRACTOR INTO SERVICE 4.4 RENEWAL OF HYDRAULIC LIFT AND ASM CONTROL UNIT 6 - In the event that the operation was not carried out correctly, the technician can cancel it by pressing A ” and restore the previous value, whereas pressing “ C ” will confirm the new setting and cause the “ CALIBRATIONS ” menu to reappear. 7 - Unlock the lift again by shifting the control lever away and then back again to the “ STOP ” position. 8 - Press “ 2 9 - Press the 'Up' button to raise the lift fully (as the lift links ascend, the “ Actual ” value should increase continuously).
10 - When the lift has reached its upper travel limit, press the Down button until the voltage reads approxi- mately 0.2V less than the value registering at the travel limit, then press “ E ” to memorize the value. 11 - In the event that the operation was not carried out correctly, the technician can cancel it by pressing A ” and restore the previous value, whereas press- ing “ C ” will confirm the new setting and cause the CALIBRATIONS ” menu to reappear. 12 - Press “ E ” to return to the main menu . 20-35 M a x . H e i g h t = = = = = = = = = = = = = = = = A c t u a l : 4 . 0 2 N e w : 0 . 9 2 [ D ] D e l e t e [ E ] E x i t M a x . H e i g h t = = = = = = = = = = = = = = = = A c t u a l :
4 . 0 2 N e w : 4 . 0 4 [ A ] C a n c e l [ C ] C o n f i r m S E T T I N G M E N U = = = = = = = = = = = = = = = = 1 - M i n H e i g h t 0 . 9 4 2 - M a x H e i g h t 4 . 0 2 3 - L o c k S p e e d 2 0 4 - S l i p a g e % 1 0 - - - M a i n L e v e r - - - 5 - T r a n s p o r t 5 . 3 6 6 - S t o p 3 . 6 6 7 - C o n t r o l 1 . 9 2 8 - F l o a t 1 . 4 5 = = = = = = = = = = = = = = = = [ E ] E x i t