Deutz — 5.1.4 ANALYSIS OF LIFT AND ASM ALARMS

5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 16 HitchControlLev. Standard alarm: 18 DESCRIPTION The control unit detects incorrect data coming from the lift control lever. NOTE In the event of the "DownSpeedPotent.", "SetPoint Potent.", CtrlMode Potent.”, MaxHeightPotent.” and “Hitch- ControlLev." alarms being displayed simultaneously, connect a test meter to pin 11 (positive) and pin 9 (negative) of connector “X14” on the control console and check that the voltage is between 7.5 and 8.5 V.

If the value is within range, check the continuity of the wiring and make certain there are no short circuits to earth or to a positive leg of the power harness between the lift control unit and the lift control console. CHECK Check that the contacts on connector “EHR” and on those of the lift control unit, “JX1” and “JX2”, are firmly attached and not oxidised. With the starter key in the “I” (ON) position, check that the power input to the lift control lever is correct (8 V approx meas- ured between pin 3 (positive) and pin 1 (negative) of connector “EHR”) Verify the correct operation of the control lever (for details see section 40).

With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “EHR” and to cab earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity). With the starter key in the “I” (ON) position, connect a test meter to pin 2 of connector “EHR” and to chassis earth, and check that there are no short circuits to positive (meter reading: 0V). With the starter key in the “O” (OFF) position, connect a test meter to pin 3 of connector “EHR” and to cab earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity).

Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed 20-53 5:51/:& ?1 * >/ 4 / !0 ?1 11 0 =  4 / !0 " 614 5 1:=400 4 /5 // 1& 9 4 / 0 =