5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 14 ASM-ShortCircuit Standard alarm: 53 DESCRIPTION The control unit detects that a solenoid valve operating the differential lock or four wheel drive, or the clutch relay, is short- circuiting. CHECK Check that the contacts on connectors “RL9” and “EVDF” and on those of the lift control unit, “JX1” and “JX2”, are firm- ly attached and not oxidised. Check that the resistance across the coil of relay RL9 is 70 Ohm approx. Test the internal resistance of the differential lock actuator solenoid (for details, see section 40).
With the starter key in the “O” (OFF) position, connect a test meter to pin 1 and pin 2 of the relay socket, and measure the resistance to verify that there are no short circuits (meter reading: infinity). With the starter key in the “O” (OFF) position, connect a test meter to pin 1 of connector “EV DF” and to chassis earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity). Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed.
20-52 0.012.8732.4 5 4 8 2 20 4 5 20 8 2 JX2 GND4 J2 TKAB2 5 2 8 GND4 F34 7.5A D7 3 5 4 +15 2 1 RL9 (DT/BRAKE) 0441.9533 13 GND2 EV DF 1 2 0.012.8672.4 D0017731 4 5 GND 5 2 1 RL9