5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 13 ShortCircuitPWM Standard alarm: 13 DESCRIPTION The control unit detects a short circuit on the control line to the lift directional control valve. CHECK Check that the contacts on connectors “EV UP” and “EV DW” and on those of the lift control unit, “JX1” and “JX2”, are firmly attached and not oxidised. Test the internal resistance of the Up and Down solenoids (for details, see section 40). With the starter key in the “O” (OFF) position, connect a test meter to pin 1 of connector “EV UP” and to chassis earth, and measure the resistance to check for short circuits to earth (meter reading: infinity).
With the starter key in the “O” (OFF) position, connect a test meter to pin 1 of connector “EV DW” and to chassis earth, and measure the resistance to check for short circuits to earth (meter reading: infinity). Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed.. 20-51 0.012.8732.4 5 4 2 1 20 4 5 20 2 1 JX1 GND4 J2 TKAB2 5 2 F34 7.5A +15 0441.9533 1920 GND2 EV DW EV UP 2 1 2 1 0.012.8672.4 D0017561 4 5 20 2 1 GND4 T 5 2 1920 2 1 2