5. ALARMS 5.1 LIFT AND ASM CONTROL UNIT ALARMS Extended alarm: 65 Radar NotConnect. Standard alarm: 41 DESCRIPTION The control unit detects that the radar is disconnected. NOTE If, when this alarm is triggered, the Infocenter indicates a wheelslip value within normal limits (on the road, wheel- slip should be zero), the fault will be on the line between the Infocenter and the transmission control unit; con- versely, if an abnormally high wheelslip value is indicated with the machine in motion (e.g. 100%), the problem is in the connection between the radar and the Infocenter.
CHECK Check that the contacts on connector “RADAR”, on connectors “ST1” and “ST2” of the Infocenter and on connectors “JX1” and “JX2” of the lift control unit, are all firmly attached and not oxidised. With the starter key in the “I” (ON) position, check that the power input to the radar is correct (12 V measured between pin 3 (positive) and pin 1 (negative) of connector “RADAR”) With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “RADAR” and to transmission earth, and measure the resistance to ensure there are no short circuits to earth (meter reading: infinity).
With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “RADAR” and pin 21 of con- nector “ST2”, and measure the resistance to verify the continuity of the circuit (meter reading: 0 Ohm). Connect a test meter to pin 5 of connector “ST1” and pin 3 of connector “JX2”, and measure the resistance to verify the continuity of the circuit (meter reading: 0 Ohm). With the starter key in the “O” (OFF) position, connect a test meter to pin 3 of connector “JX2” and to cab earth, and measure the resistance to ensure there are no short circuits to earth (meter reading: infinity).
With the starter key in the “I” (ON) position, connect a test meter to pin 3 of connector “JX2” and to chassis earth, and check to ensure there are no short circuits to positive (meter reading: 0V. Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the control unit must be renewed. 20-68 5 4 3 0.012.8732.4 20 JX1 4 5 20 3 JX2 AS3 ST1 21 5 RADAR OUTPUT GND4 2 21 RADAR INPUT AS2 ST2 J2 TKAB2 0.012.8894.4 4 5 20 ST1 1 5 RADAR OUTPUT 21 RADAR INPUT ST2 0.012.8894.4 2 AS2 TKAB2 5 2 1 F34 F27 7.5A 3A +15 0441.9533 5 2 1 10 1 GND2 RADAR 2 3 1 0.012.8672.4 D0017671 5 RADAR OUTPUT RADAR INPUT 21