5. ALARMS 5.2 LIST OF TRANSMISSION CONTROL UNIT ALARMS ALARM N° 13 DESCRIPTION The control unit detects a problem with the power input to the temperature sensor. ECU RESPONSE The control unit does not limit the operation of the transmission, but sets the transmission temperature to the “Trans- mission cold” default value (HK pedal holding time, splitter holding time, slip times). CHECK Check that the contacts on connector “TEMP” and on that of the lift control unit, “ECU PS”, are firmly attached and not oxidised. Verify the correct operation of the sensor (for technical details, see section 40).
With the starter key in the “O” (OFF) position, connect a test meter to pin 1 of connector “TEMP” and to transmission earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity). With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “TEMP” and to transmission earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity). Clear all alarms, turn the starter key first to “O” (OFF) and then back to the “I” (ON) position again, and if the alarm is still present, the transmission control unit must be renewed.
20-86 0.012.8732.4 1 2 21 23 45 24 39 68 2145 23 68 1 2 39 24 ECU PS GND4 J2 TKAB1 3 6 1020 F35 F27 TEMP 7.5A 7.5A 2 1 +15 +30 0441.9533 0.012.8672.4 D0017121 0.012.8732.4 1 2 21 23 45 24 39 68 2145 23 68 1 2 39 24 ECU PS GND4 J2 TKAB1 3 6 F35 F27 7.5A 7.5A +15 +30 0441.9533 1020 TEMP 2 1 0.012.8672.4 21 45 23 68 1 2 39 24 GND4 J2 3 10 20 2 1