5. ALARMS 5.3 LIST OF ALARMS DISPLAYED BY SERDIA SERDIA ALARM N° 7 DESCRIPTION The engine control unit has detected that the engine turbo charge pressure signal is either non-existent or unreliable. CHECK Check for electrical continuity between pin 1 of connector “B48” and pin 23 of connector “MX1”. Check for electrical continuity between pin 4 of connector “B48” and pin 24 of connector “MX1”. Check for electrical continuity between pin 3 of connector “B48” and pin 25 of connector “MX1”. Verify the correct operation of the sensor (for technical details, see section 40).
Check that the power input to the sensor is correct (5 Vdc approx measured between pin 3 (positive) and pin 1 (negative) of connector “B48”). With connector “MX1” unplugged from the engine control unit and the starter key in the “I” (ON) position, connect a test meter to pin 2 of connector “B48” and to engine earth, and check that there is no voltage registering (meter reading 0V). With the starter key in position “O” (OFF), connect a test meter to pin 2 of connector “B48” and to engine earth, and measure the resistance to verify that there are no short circuits to earth (meter reading:
infinity) 20-145 0.012.8732.4 25 10 24 23 2 14 1 10 23 24 25 MX1 1 2 14 MX2 GND4 MS1 J1 10 2 3 24 25 1 0.013.5915.4 7 29 2 7 7 F30 7.5A +15 0441.9533 23 24 25 B48 1 4 3 2 p 0421.3172 3 24 2 5 4 3 2 D0023020 1 2 14