5. ALARMS 5.3 LIST OF ALARMS DISPLAYED BY SERDIA SERDIA ALARM N° 9 DESCRIPTION The engine control unit has detected that the coolant temperature signal is either non-existent or unreliable. CHECK Check for electrical continuity between pin 1 of connector “B43” and pin 9 of connector “MX1”. Check for electrical continuity between pin 2 of connector “B43” and pin 8 of connector “MX1”. Check that the temperature sensor functions correctly and does not give a false reading; use an infrared thermometer and compare the reading with the value received from the sensor by the engine control unit. Check that the coolant level is within normal limits.
Check with the Serdia program that the parameters “510 CoolantTempWarn” (normal value: 122 °C) and “514 Cool- antTempEcy” (normal value: 130 °C) are correct. Verify the correct operation of the sensor (for technical details, see section 40). With connector “MX1” unplugged from the engine control unit and the starter key in the “I” (ON) position, connect a test meter to pin 1 of connector “B43” and to engine earth, and check that there is no voltage registering (meter reading 0V).
With connector “MX1” unplugged from the engine control unit and the starter key in the “I” (ON) position, connect a test meter to pin 2 of connector “B43” and to engine earth, and check that there is no voltage registering (meter reading 0V). With the starter key in the “O” (OFF) position, connect a test meter to pin 1 of connector “B43” and to engine earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity). With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “B43” and to engine earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity) .
20-146 0.012.8732.4 10 9 8 2 14 1 10 9 8 MX1 1 2 14 MX2 GND4 MS1 J1 2 0.013.5915.4 4 22 7 F30 7.5A +15 0441.9533 9 8 B43 1 2 0421.3172 t° 8 D0022721 10 9 8 1 2 14