5. ALARMS 5.3 LIST OF ALARMS DISPLAYED BY SERDIA SERDIA ALARM N° 52 DESCRIPTION The engine control unit has detected that the reference signal for the position of the actuator does not match the re- quirement. CHECK Check that the contacts on connector “Y3” and on the control unit “MX1” are firmly attached and not oxidised. Check for electrical continuity between pin 5 of connector “Y3” and pin 18 of connector “MX1”. Check that the internal resistance values for the actuator are correct (for details see section 40).
With the starter key in the “I” (ON) position and the engine 'off', connect a test meter to pin 5 of connector “Y3” and to engine earth, and check that there is no voltage registering (meter reading: 0V). With the starter key in the “O” (OFF) position, connect a test meter to pin 5 of connector “Y3” and to engine earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity). If the fault persists, renew the actuator.
20-153 0.012.8732.4 10 19 18 17 2 16 1 15 14 10 14 15 17 19 18 16 MX1 1 2 14 MX2 GND4 MS1 J1 10 14 15 1 7 19 18 16 4 0.013.5915.4 GND2 4 6 1 0 11 1 9 7 F30 7.5A +15 0441.9533 1415 17 19 18 1 2 3 4 5 Y3 0429.3172 1 4 15 1 7 19 1 8 1 2 3 4 5 D0022741 1 2 14