5. ALARMS 5.3 LIST OF ALARMS DISPLAYED BY SERDIA SERDIA ALARM N° 53 DESCRIPTION The engine control unit has detected that the difference between the command and the response of the actuator is greater than 10%. CHECK Check that the internal resistance values for the actuator are correct (for details see section 40). Check that the injection pumps control rod slides freely. Check that the fuel injection pumps have not seized. Check that the contacts on connector “Y3” and on the control unit “MX1” are firmly attached and not oxidised. Check for electrical continuity between pin 4 of connector “Y3” and pin 19 of connector “MX1”.
Check for electrical continuity between pin 5 of connector “Y3” and pin 18 of connector “MX1”. 20-154 0.012.8732.4 10 19 18 17 2 16 1 15 14 10 14 15 17 19 18 16 MX1 1 2 14 MX2 GND4 MS1 J1 10 14 15 1 7 19 18 16 4 0.013.5915.4 GND2 4 6 1 0 11 1 9 7 F30 7.5A +15 0441.9533 1415 17 19 18 1 2 3 4 5 Y3 0429.3172 1 4 15 1 7 19 1 8 1 2 3 4 5 D0022741 1 2 14