Deutz — 5.4.4 ANALYSIS OF ALARMS

5. ALARMS 5.4 LIST OF FRONT AXLE SUSPENSION CONTROL VALVE ALARMS ALARM N° 19 Battery V. Low DESCRIPTION The control unit has detected that the battery voltage is too low (less than 10V). NOTE This alarm is activated generally when the battery voltage is less than 10V and can be tripped by an excessive cur- rent draw when the engine is started, or if the battery is damaged or cannot be recharged by the alternator. Accordingly, this alarm can be displayed only as a passive alarm by the ART. Should the alarm be displayed among the active alarms, the ECU must be renewed. CHECK See if the alarm is indicated as an active alarm; if so, the ECU must be renewed.

Check, with the engine off, that the battery voltage is as prescribed (higher than 12V); if not, install a new battery. NOTE Lower voltages can register after the tractor has been standing idle for an extended period; this does mean nec- essarily that the battery needs replacing. Check first whether or not the battery voltage returns to normal with the engine running. In this instance the problem may be attributable to the battery being discharged or damaged; if not, and the voltage remains lower than the pre- scribed minimum, the trouble is being caused by incorrect operation of the alternator.

NOTE In extreme cases, when the battery is seriously damaged (short-circuiting), the alternator may not be able to re- charge the cells or generate sufficient voltage. Before changing the alternator, verify its correct or incorrect op- eration by connecting a new battery. 20-170