Deutz — 5.4.4 ANALYSIS OF ALARMS

5. ALARMS 5.4 LIST OF FRONT AXLE SUSPENSION CONTROL VALVE ALARMS ALARM N° 21 SC LAMP Ind. DESCRIPTION The control unit has detected that the activation and faults indicator light is short-circuiting. NOTE This alarm is displayed only by the ART. The operator or technician may become aware of the problem simply due to the fact that the lamp does not light up when the front axle suspension is activated or deactivated. CHECK Check that the contacts on connector “5” of the activating switch and connector “JX4” of the control unit are firmly at- tached and not oxidised .

With the starter key in the “O” (OFF) position, connect a test meter to pin 10 of connector “5” and to cab earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity). If the fault persists, renew the control unit.. 20-171 0443.7850 20 5 4 8 12 5 4 20 JX3 12 8 JX4 FE1 5 4 20 12 8 3 8 0.012.8732.4 GND4 J2 AS1 3 8 10 9 AS3 7 F17 7.5A +15 0441.9533 3 21 12 3 5 9 10 1 5 0.012.8894.4 21 12 3 9 10 10 1 D0017250