5. ALARMS 5.4 LIST OF FRONT AXLE SUSPENSION CONTROL VALVE ALARMS ALARM N° 24 ALL. CC EV UP DESCRIPTION The control unit detects a short circuit in the control line of the front axle 'up' solenoid. CHECK Check that the contacts on connector “JX3” of the control unit and connector “H” of the front axle up valve solenoid are firmly attached and not oxidised . Test the internal resistance of the solenoid (the resistance value must be other than 0 Ohm). With the starter key in the “O” (OFF) position, connect a test meter to pin 2 of connector “H” and to chassis earth, and measure the resistance to verify that there are no short circuits to earth (meter reading: infinity).
If the fault persists, renew the control unit. 20-173 0443.7850 20 5 4 1 JX3 1 20 4 5 FE2 0.012.8732.4 FE1 8 GND4 3 J2 1 7 2 1 H 0443.7849 7 F17 7.5A +15 0441.9533 D0017210 1 20 4 8 3