EDS (Electronic Diagnosis System) POWER-SHUTTLE DIAGNOSISPROGRAMM DEST 45 20-205 Remarks • Only for T7200 • Possibly sequence error from LU VPS2 • KM can only be diagnosed in dis- connected state • Self preservation • Only for T7200 • Possibly sequence error from LU VPS2 • Self preservation • Can also lead to error ”VPS2-Plausi” (Int.
EC:47) • K+ can only be diagnosed in con- nected state • Only for T7200 • Possibly sequence error from LU VPS2 • LU can only be diagnosed in dis- connected state • Only for T7200 • Possibly sequence error from LU VPS2 • KM can only be diagnosed in dis- connected state • Self preservation • Only for T7200 • Possibly sequence error from LU VPS2 • Self preservation • Can also lead to error ”VPS2- Plau- si” (Int.
EC:47) • K+ can only be diagnosed in con- nected state possible remedy Check cabling Check valve Check valve supply (VPS2) Check cabling Check valve Check valve supply (VPS2) Check cabling Check valve Check valve supply (VPS2) Check cabling Check valve (VPS2) Check valve supply Check cabling Check valve Check valve supply (VPS2) System reaction Operation mode STAND-BY STRATEGY (Powershift blocked) Operation mode STAND-BY STRATEGY (Powershift blocked) Operation mode STAND-BY STRATEGY (Powershift blocked) Operation mode STAND-BY STRATEGY (Powershift blocked) Operation mode STAND-BY STRATEGY (Powershift blocked) Error location/error cause Retaining valve 2 KM Retaining valve 2 K+ Retaining valve 1 LU Retaining valve 1 KM Retaining valve 1 K+ Code 31 32 33 34 35