EDS (Electronic Diagnosis System) DIAGNOSIS OF THE INFOCENTER 4. PREPARATIONS FOR DIAGNOSIS OF THE INFOCENTER As a preparatory measure the connection between tractor (infocenter) and computer needs to be established so as to check the infocenter by means of the EDS program resp. to change the constant values. The interface cable and the adapt- er cable are serving for this purpose (see figure). Fig. 51 - Interface cable and adapter cable 1 - Connect plug (1) of the interface cable with the designation ”EIC” to the computer (COM interface).
2 - Connect plug (3) of the interface cable for the 12 V supply to the cigar lighter 3 - Connect the 2-pole plug (4) of the interface cable to the plug (10) – designation ”Info center” – of the adapter cable 4 - Insert the central plug (8) of the adapter cable into the central diagnosis interface in the fuse box 5 - Switch on ignition 6 - Start the computer and call the EDS program (compare item A 1.3 – Launching and terminating of the EDS program) 7 - Make sure that the right option is called in the initial menu: Option 4 -> plug (2) with the designation ”9141” to interface COM 1 Option 5 -> plug (2) with the designation ”9141” to interface COM 2 NOTE.
Agrotron tractors with the vehicle identification numbers up to 80xx 1999 (i.e. green cabin) usually are not equipped with a central diagnosis interface. To be able to check the Infocenter however, with these tractors it is necessary to connect the 2-pole plug of the interface cable directly with the diagnosis terminal of the Infocenter. The diagnosis terminal is located in the cable harness at the backside of the Infocenter. 20-221