EDS (Electronic Diagnosis System) POWER-SHUTTLE DIAGNOSISPROGRAMM DEST 45 Only one plug is connected OUTPUT not connected Error code on display Standby driving possible INPUT not connected Error code on display Plausibility Standby driving possible 3.11.4 LOCKING MAGNET FIELD/STREET AND TEMPERATURE SENSOR T-7100 L Both elements are equipped with Jet-Tronic connectors; distance approx. 115 mm Locking magnet plug on temperature sensor 3.11.5 PLUG DRIVING CLUTCH NHK ON OUTPUT/GROUND SPEED NAB AND VICE VERSA WITH T-7200 L (both plugs are connected) Tractor is starting for a short time Error message ”91” on display: Powershift gear in neutral 20-220