EDS (Electronic Diagnosis System) DIAGNOSIS OF THE INFOCENTER The values of charge control and terminal 15 reference will change when the engine is running: Check analog inputs: 0 Tank 11,4% analog value 1 Tem perature 100% analog value 2 Charge control 100% analog value 3 Term inal 15 reference 13,7 Volt term inal 15 voltage Analog inputs > Tank The signal of the tank transducer at plug X 131, pin 13 of the INFOCENTER is tested: The indicated % value corre- sponds to the actual tank level. It is the percentage of the existing terminal 15 reference. When the plug is pulled off from the tank transducer 100% will be indicated.
Analog inputs > Temperature The signal of the temperature sensor (engine coolant) at plug X 131, pin 15 of the INFO-CENTER is tested. The relation between the input signal and the reference voltage terminal 15 is indicated in %. Analog inputs > Charge control The signal of the charge control for the electric generator at plug X 131, pin 7 of the INFO-CENTER is tested. When the engine is running a display of 100% indicates proper charging by the electric generator. Analog inputs > Terminal 15 reference The power supply on terminal 15 at plug X 130, pin 2 of the INFOCENTER is tested. The indication 13,7 V is the actual operating voltage. Press the ENTER key to return to the TEST MODE.
TEST MODE > F6 POINTER Upon pressing the key F6 the following window appears: The cursor is flashing behind “engine speed angle”. Engine speed angle signifies Revolution Counter Angle. Fig. 60 - Move pointer to position Pointer > Engine speed angle Enter an angle, e.g. 180. - Display: DZM angle 180 After pressing the ENTER key the pointer of the engine speed indication will move from its 0 position by 180 (to about 1900 rpm). 20-230