Deutz — 3.6 STOP

ALL ROUND TESTER FOR LIFT AND ASM CONTROL UNIT 3. CALIBRATIONS 3.5 TRANSPORT The voltage value relative to the TRANSPORT position of the lift control lever is programmed and stored in the ECU mem- ory. The value can be changed by putting the lift lever in the TRANSPORT position and confirming the new value by pressing . The permissible range is 4.70V to 6.69V. C 3.6 STOP The voltage value relative to the STOP position of the lift con- trol lever is programmed and stored in the ECU memory. The value can be changed by putting the lift lever in the STOP position and confirming the new value by pressing . The permissible range is 3.00V to 4.32V.

C 20-247 T R A N S P O R T = = = = = = = = = = = = = = = = 1 - A C T U A L # # # # 2 - N E W # # # # [ A ] C a n c e l [ C ] C o n f i r m S T O P = = = = = = = = = = = = = = = = 1 - A C T U A L # # # # 2 - N E W # # # # [ A ] C a n c e l [ C ] C o n f i r m