ALL ROUND TESTER FOR LIFT AND ASM CONTROL UNIT 3. CALIBRATIONS 3.7 CONTROL The voltage value relative to the CONTROL position of the lift control lever is programmed and stored in the ECU memory. The value can be changed by putting the lift lever in the CON- TROL position and confirming the new value by pressing . C The permissible range is 4.70V to 6.69V. 3.8 FLOAT The voltage value relative to the FLOAT position of the lift control lever is programmed and stored in the ECU memory. The value can be changed by putting the lift lever in the FLOAT position and confirming the new value by pressing . The permissible range is 3.00V to 4.32V.
C 20-248 C O N T R O L = = = = = = = = = = = = = = = = 1 - A C T U A L # # # # 2 - N E W # # # # [ A ] C a n c e l [ C ] C o n f i r m F L O A T = = = = = = = = = = = = = = = = 1 - A C T U A L # # # # 2 - N E W # # # # [ A ] C a n c e l [ C ] C o n f i r m