Deutz — 3.5 CAN STATUS

SERDIA MEASURED VALUES SERDIA rejects CabRxObjActive in bit mode (inactive message) and then carries out a bit-mode AND logic operation with CanConf_bits. The receipt messages which are configured and inactive (CanRxTimeOutBits) are received in bit mode as a result. A text is assigned to each bit of CanRxTimeOutBits; this text contains the name of the respective receipt messages. Be- cause not all bits have to be used, entering "dc", for "don't care" into the text specifies that the text output for this bit is sup- pressed. If the text "100 receipt message failed" appears, a list of the missing receipt messages will also be output. Example of displayed error information:

100 Receipt message failed Engine Temperature Engine Fluid Level /Pressure Function shift Inlet / Exhaust Conditions 20-282 VanRxTimeOutBit Text 0 Engine Temperature 1 Inlet / Exhaust Conditions 2 Engine Fluid Level /Pressure 3 TSC1 4 Engine protection 5 Function shift