Deutz — 4.1 CONFIGURATION (GENERAL)

SERDIA PARAMETERS 4. PARAMETERS 4.1 CONFIGURATION (GENERAL) IMPORTANT: 1 - For safety reasons, the original data set should be saved before making any changes. 2 - Engine running tests are allowed for PID parts only, and should only be carried out by suitably qualified personnel. 3 - Incorrect settings may cause damage to the engine! CONFIGURATION PROCEDURE Select the "Parameters" menu on the menu bar to go into the "Configuration" screen. A configuration is carried out in the following steps: On the top line, click on the tab for the desired page or Using the "Next" and "Previous" buttons, browse to the page that contains the parameter to be set (For example: ’Ac- cPedal (SWG1)up.

ref’ on page 10: Setpoint gen. calibration values). Click in the "New value" field, and enter the required value. This should be between the indicated minimum and max- imum values. Click on the "PC->ECU" button. All configuration data are transferred to the control unit. The data are now in the control unit and can be used for testing the engine setting. When the supply voltage is switched off, this data is lost. Next step using the "Save in ECU" button, save the data set in the control unit (the old data are overwritten). For checking, the data can be read and displayed by clicking the "ECU->PC" button.

When the engine is running satisfactorily, click on the "Save in file" button to save the data on hard disk or diskette. DESCRIPTION OF SCREEN BUTTON: CENTR.->PC: Configuration data are read from the control unit and displayed. PC->CENTR.: Modified configuration data are transferred into the control unit. In the case of the EMR1, the "Save in ECU" button must be used to store the data permanently. Open file: Configuration data are read from a file (*.hex) and displayed. Save in file : All configuration data are stored in a file (*.hex). When saving, the engine number is prompted as the file name - this is only a suggestion. Any other name can be entered. Finally, click OK to confirm.

The file (i.e. the engine data set) is then saved under the name .hex. 20-283