SERDIA PARAMETERS Save in ECU (EMR1 only): The configuration data are stored in the control unit. ATTENTION! All modifications must be reported back! The reporting procedure is described in Service Announcement 0199-99-9287. Previous : The data on the previous screen are displayed. Next : The data on the next screen are displayed. Print : Print the displayed configuration data on the printer. The configuration window can be printed page by page, or in sets (from Page ... to Page ...), or in full. 4.2 OVERALL PROGRAMMING Saving data from the control unit: By clicking "ECU->file“ menu, read the data from the control unit. The "Save as" window opens.
Save the data under any name, in the form .hex. The default name .hex is suggested; this can be replaced by any other name. Confirm by clicking OK. The file (i.e. engine data set) is saved under the selected filename. Overall control unit programming. Click on the "Programming" button; the "Open" window appears. Select the desired file and open it. Click on the "Save in ECU" button. Of the configuration data, only the operating data read from the control unit (Column 2) or file (Column 3) are displayed. Be- fore the configuration data are transferred to the control unit, the operating data can be edited in Column 4.
This data is also transferred to the control unit along with the configuration data. Overall programming is not allowed at user Level I or II. EMR1 EMR2 DESCRIPTION OF SCREEN BUTTON: ECU->file : Configuration data are read from the control unit, displayed, and saved as a HEX file. PROGRAMMING: The modified configuration data, or the configuration data HEX file, is transferred to the control unit. In the case of the EMR1, the "Save in ECU" button must be used to store the data permanently. Save in ECU : Configuration data are permanently stored in the control unit. 20-284