SERDIA PARAMETERS 4.2 CALIBRATION System components can only be calibrated through the diagnostic interface. The SERDIA diagnosis software is required for the calibration. Along with the EMR1, the accelerator pedal and hand throttle potentiometer (if present) must also be cal- ibrated (does not apply to large assemblies). Important conditions: Engine off Supply voltage (Ignition/Circuit 15) on Integrated accelerator pedal EXPLANATION OF CONCEPTS (EXAMPLES): Acceler(SWG1) = Acc. pedal sensor (position sensor 1), Input 24 FS Hand throttle(SWG2) = Hand throttle pot. (position sensor 2), Input 20 FS GENERAL CALIBRATION PROCEDURE: Select calibration value in the upper window.
Place accelerator pedal/Manual throttle potentiometer in the desired position. "Get value“ button enabled: Click the button. The calibration value assigned to the position appears in the Edit field. "Get value“ button disabled: Enter the calibration value in the Edit field. By clicking "PC->ECU", transfer the calibration value to the control unit. By clicking "Save in ECU", save the calibration value in the control unit. Switch the ignition on and off. SCREEN BUTTON DESCRIPTION: Get value : If the "Get value" button is enabled, it can be used to read the calibration value for a pedal position. PC->ECU : The displayed calibration value is transferred to the control unit. Save in ECU :
The calibration data are permanently stored in the control unit. 20-285