SERDIA ERROR MEMORY The following table can be used to assist in the elimination of possible causes of errors which have occurred. When doing this, the status of the fault indicator must be noted: Permanent light: Error statuses permitting limited engine operation. The error must be eliminated as quickly as possible to avoid further damage. Flashing light: Error statuses resulting in the engine being shut off or preventing the engine from being started. The error must be eliminated so that the engine can be put back into operation. ERROR MESSAGES, CAUSES AND REMEDIES 20-288 Error pilot lamp Error messages (only readable with Serdia) Possible causes Remedy Type of error Error location n. O.K.
Permanent light (Engine opera- tion restricted) (0) 8120:(F24)AccelerPedal(SWG1)1 8130:(F20)HandThrottle(SWG2)2 8140:(M9)CoolantTempSensor3 8150:(M24)BoostPressureSensor 8160:(M21)OilPressureSensor 8170:(M13)Speed 1, camshaft4 8180:(M11)Speed 2, terminal W 8190: (intern)ElectronicsTemperature Plug-in connection inter- rupted Restore plug-in connection OK Plug-in contacts contam- inated or corroded Clean connector and replace if necessary OK Sensor defective Replace sensor OK Cable harness defective Check cable harness and re- place if necessary (2) 8002: (F18)Signal monitoring PWMInp1 8012: (F21)Signal monitoring PWMInp2 PWM signal cannot be evaluated Check signal (3)5 8343:Coolant temp.
monitoring 8363:Oil pressure monitoring Temperature warning limit exceeded too long. Fallen below oil pres-sure alarm limit for too long. Check coolant Check oil level Faulty configuration. Check data in SERDIA menu Check ”configuration” and change if necessary (5)6 8305:Speed monitoring Overrun cond. activated. Flashing (Engine off) (0) 8170:(M13)Speed 1, camshaft7 Plug-in connection interrupted Restore plug-in connection OK Plug-in contacts contaminated or corroded Clean connector and replace if necessary OK Sensor defective Replace sensor OK Cable harness defective Check cable harness and replace if necessary