SERDIA ERROR MEMORY 1 Switch to SWG 2 (if SWG 2 available). Fixed speed with 2% speed droop is set. 2 Switch to SWG 1 (if SWG 1 available). Fixed speed with 2% speed droop is set.. 3 Electronics temperature is evaluated. 4 Continued running with reduced rated speed, if speed sensor 2 is available. 5 Injected fuel limitation (if activated). 6 The measured value exceeds maximum speed. 7 Speed sensor 2 not available or defective. It is recommended to use a multimeter as measurement aid.
20-289 Flashing (Engine off) (2) 8112:(M17)Rack travel sensor Plug-in connection interrupted Restore plug-in connection OK Plug-in contacts contaminated or corroded Clean connector and replace if necessary OK Actuator defective Replace actuator OK Cable harness defective Check cable harness and replace if necessary (5) 8305:Speed monitoring Overspeed reached 8345: Eng.OFF->CoolantTempMonit. 8365: Eng.OFF->OilPressMonit Temperature alarm limit exceeded for too long. Fallen below oil pres-sure alarm limit for too long. Check coolant Check oil level Faulty configuration (e.g. overrun cond. OFF).
Check data in SERDIA menu ”Configuration” and change if necessary 8405:Actuator (positioner, travel meter, fuel rack) Actuator defective Replace actuator (Engine start not possible) a) Flashing b) Flashing or Permanent light c)Off (0) 8210:Data loss EEPROM 8220:Data loss coil data 8020:ECU (positioner actuation) Battery or cable harness defective, ECU failure Check battery Check cable harness Replace ECU Error in central electron- ics, pro-gram in EMR was not executed Replace ECU (0) 8170:(M13)Speed 1, camshaft7 Plug-in connection inter- rupted Restore plug-in connection OK Plug-in contacts contaminated or corroded Clean connector and replace if necessary OK Actuator defective Replace actuator OK Cable harness defective Check cable harness and re- place if necessary (5) 8405:
Actuator (positioner, travel meter, fuel rack) Actuator defective Replace actuator