SERDIA EMR2 ERROR TABLE 5.1.2 EMR2 ERROR TABLE 20-291 Help No active faults present Check distance. Check cable connection. Check sensor and replace if re- quired. Check cable connection and tacho. Replace if required. Check parameter (21). Check speed settings. Check PID setting. Check rods. Check actuator and replace if required. Check cable to actuator ( impulse on incorrect speed). Check no. of teeth. For vehicles check for possible thrust mode. Check sensor cable. Check sensor and replace if required. Check fault limits for sensor. Remarks Governor in emergency operation (if sensor 2 available). Emergency switchoff (if sensor 2 not available or failed).
Governor in emergency operation (with sensor 1) Emergency switchoff (if sensor 1 not available or failed). Governor in emergency operation. (see Chapter 4.15). Engine stop. (see Chapter 4.3.3) See Chapter 4.15 influencing fault reaction. With failure of the sensor, the associated monitoring function is de-activated. Cause Sensor failure. Distance from gear too far. Additional fault impulses. Cable joint interrupted. Tacho failed. Additional fault impulses. Cable connection interrupted. Speed was/is in excess of limit. e. Fault at corresponding sensor entry (e.g. short circuit or cable break). Blink codee horts 0,4 s - 1 2 3 4 1 2 3 4 5 6 7 long 0,8 s - 1 1 1 1 2 2 2 2 2 2 2 Ricon.
EMR short 0,4 s 2 2 2 2 2 2 2 2 2 2 2 2 Fault locality/ Fault description No faults Speed sensor 1 Speed sensor 2 Speed sensor Excess speed switch Set point sensor 1 accelerator pedal) Set point sensor 2 (hand throttle) Charge air pressure Oil pressure Coolant temperature Charge air temperature Fuel temperature Fault no. (in SERDIA) - 01 03 04 05 06 07 08 09 10 11 Fault group Zero error display Revolutions / speed acquisition Sensors