Deutz — 7.1 EMR1

SERDIA TASKS Screen button functions: ECU->PC : Configuration data are read from the control unit and displayed. PC->ECU : Modified configuration data are transferred into the control unit. To store the data permanently, use the "Save in ECU" button. Save in ECU : Configuration data are permanently stored in the control unit. All modifications must be reported back! The reporting procedure is described in Service Announcement 0199-99-9287. Graphics : The "Graphics" button can be used to see a graphical representation of the selected measurement quan- tities over time (5 maximum). If more than 5 quantities are selected, an error message is displayed. Collect. time :

The measurement collecting time is indicated in the "Collect. time" box, in seconds. The smallest unit of collecting time is one second. The highest time may be several hours (specified in seconds). The basic setting is 10 s. The shortest scan rate is 40 ms for RAM values 60 ms for other values. A measurement time of 10 s gives 10000 ms/40 ms = 250 measurement points for RAM values 10000 ms/60 ms = 166 measurement points for other values. Since the program takes around 2000 measurement points maximum, the scan rate is adapted automatically before data collection begins. The lowest possible scan is determined by the duration of data transfer from the control unit to the PC.

The higher the number of measured quantities to be displayed at the same time, the longer the data transfer time, and the narrower the scan frequency. Print : Prints the measured values appearing on the screen. Close : Return to the "Tasks" menu. 20-300