ENGINE MAINTENANCE - Maintenance Procedures 2. Unscrew the four bolts (1) using a ratchet with 10 mm socket. 3. Remove the motor from the housing and take out the filter. 4. Remove the gasket from the motor as well as the gasket from the housing, and wipe the two gasket grooves with a clean, lint-free rag. 5. Properly dispose of the filter and gaskets. Do not remove the retaining ring e-clip from the shaft. The e-clip (1) being slanted is OK (2). CCV Filter/Motor Installation 1 2 CCV Retainer Ring Installation How to Reassemble a CCV Unit Reassembly instructions for servicable Crankcase Ventilation (CCV) modules 3 2 1 2 1. Housing 2. Motor 3.
Mounting Flange Follow the steps below to reassemble the CCV after the old filter and gaskets have been removed. Y53-1181-1K1 (08/2018) 57