Doosan DX225LC-3 — Check Air Compressor and Drain Water as Required

DX225LC-3 Inspection, Maintenance and Adjustment 4-38 Grease Leveling Blade Pins (Optional) NOTE: Grease leveling blade every 10 hours during initial break-in period of 100 hours. After break-in period grease it every 50 hours thereafter. NOTE: In case of performing work in water, grease it every 10 hours. 1. Lower leveling blade to the ground. 2. Inject grease at 3 points per blade cylinder (6 points total) using grease gun. FG009564 Figure 39 3. Remove old grease that has been purged out after greasing. Drain Water and Sediment from Fuel Tank 1. Perform this procedure before operating the machine. 2. Drain water and sediment from bottom of fuel tank into an approved container. NOTE:

Dispose of drained fluids in compliance with all applicable environmental laws and regulations. NOTE: Always completely fill fuel tank at end of each workday to prevent condensation from forming on the inside walls of the tank. FG020064 Figure 40 Check Air Compressor and Drain Water as Required 1. Set air compressor operating switch to "I" (OFF) position. 2. Using air gun in the cabin, completely release all air in compressor tank. 3. The air compressor drain valve (1, Figure 41) is on the bottom of the battery box, on right side of the machine. 4. Put a pan under the drain valve, push valve handle (1, 1 FG020058 Figure 41) sideways to drain water.

Figure 41 WARNING AVOID DEATH OR SERIOUS INJURY The drain valve does not work when the pressure in the air compressor tank is 1.0 bar (14 psi) or above. Compressed air inside tank must be released first. Wear safety goggles to protect your eyes from water and/or flying objects from drain valve. FG009564