Doosan DX225LC-3 — Change Swing Reduction Device Oil (Drain and Refill After First 500 Hours)

Check Oil Level in Travel Reduction Device (One on Each Side of Unit) 3 WARNING 1 The gear oil is very hot after the machine has been operating. Shut all systems down and allow them to cool. AVOID DEATH OR SERIOUS INJURY 2 EX1300564 Before removing the motor case, loosen the plug slightly to allow pressurized air to escape. Residual pressure in the travel reduction device can cause the plug to be dislodged and oil to squirt out suddenly. Figure 78 1. Make sure that the machine is on firm and level ground. 2. Rotate the track until ports (1 thru 3, Figure 78) are in their proper positions as shown. 3. Loosen fill plug (3, Figure 78) slightly to allow pressurized air to escape. 4.

Remove oil level plug (1, Figure 78). 5. Check oil level. The oil must be near the bottom of the level plug opening. 6. Add oil through the fill plug (3, Figure 78) opening, if necessary. 7. Clean and install oil level and fill plugs (1 and 3, Figure 78). 8. Repeat this procedure on the other travel reduction device. Change Oil in Travel Reduction Device (One on Each Side of Unit) (After First 500 Hours) NOTE: Drain and refill oil after first 500 hours of operation or rebuild, and every 1,000 hours thereafter (See page 4-60). Change Swing Reduction Device Oil (Drain and Refill After First 500 Hours) NOTE:

Change swing reduction device oil after first 500 hours on a new machine and every 1,000 hours thereafter (See page 4-61). DX225LC-3 Inspection, Maintenance and Adjustment 4-56 Reference Number Description 1 Oil Level Plug 2 Drain Plug 3 Fill Plug