Doosan DX225LC-3 — Change Hydraulic Oil Tank Breather Filter

1,000 HOUR / 6 MONTH SERVICE Perform All Daily, 50, 250 and 500 Hour Service Checks Grease Swing Reduction Device 1. Park machine on firm and level ground. Lower the front attachment to the ground and stop engine. 2. Remove air vent plug (1, Figure 79) from swing reduction device. 1 Figure 79 FG020089 3. Press grease fitting and inject grease with the grease gun on the marked point (2, Figure 80). 4. Install air vent plug (1, Figure 79) in swing reduction device. FG020090 2 Figure 80 Change Hydraulic Oil Tank Breather Filter 1 1. Park machine on firm and level ground. Lower the front attachment to the ground and stop engine. 2. Tip breather cap up (2.

Figure 81) slightly to release the internal pressure. 2 3. Unscrew the bolt (1, Figure 81) and take off the breather cap (2). 3 4. Change a filter cartridge (3, Figure 81) and assemble the breather cap by tightening the bolt. NOTE: Used filter should always be disposed of according to local regulations. NOTE: When the machine is operated under dusty work sites, the air breather filter needs to be cleaned or replaced on a regular basis even before the expected replacement date. FG013207 Figure 81 Inspection, Maintenance and Adjustment 4-57 DX225LC-3