Replace Hydraulic Oil Return Filter NOTE: Change hydraulic oil return filter after first 250 hours of operation or rebuild, and every 1,000 hours thereafter. AM H H NOTE: If return filter clogged warning symbol (Figure 82) on display monitor comes "ON" the return filter must be serviced. E F C C rpm FG018717 s DIG ISO USB Min Max Figure 82 WARNING 1 3 2 AVOID DEATH OR SERIOUS INJURY The hydraulic oil will be hot after machine operation. Allow the system to cool before attempting to service any of the hydraulic components. The hydraulic tank is pressurized. Tip the hydraulic breather cap up slightly to allow the pressurized air to vent.
After the pressure has been released, remove service covers or drain water from tank. Figure 83 FG020079 IMPORTANT Make sure to clean any dirt or water from the top of the hydraulic tank, especially around the fill port and filter ports. 1. Park machine on firm and level ground. Lower the front attachment to the ground and stop engine. 2. Tip breather cap up (1, Figure 83) slightly to release the internal pressure. 3 6 7 3. Remove bolts (2, Figure 83) and service cover (3). Remove spring (4), valve (5) O-ring (6), and bypass strainer (7), and then filter (8). 5 8 4. Remove filter and discard. NOTE: Used filter should always be disposed of according to local laws and regulations. 5.
Install new filter and a new O-ring. Install bypass strainer, valve and spring. Install service cover plate. 6. Run engine for ten minutes at "LOW IDLE" to purge air from circuit. 7. Check level in hydraulic oil tank (See page 4-25). Add oil if necessary. FG021266 Figure 84 DX225LC-3 Inspection, Maintenance and Adjustment 4-58