Check Air Conditioner Refrigerant WARNING AVOID DEATH OR SERIOUS INJURY Mixing of tobacco smoke and freon is deadly. Do not smoke while servicing or recharging air-conditioning system. FG019404 Contact with refrigerant can result personal injury, frost bite. Wear Protective glasses when refrigerant lines are opened. Figure 95 System may still under pressure, release it slowly in a well ventilated area. Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.
Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system. 1. Run engine at about 1,800 rpm. Operate for a minimum of ten minutes to stabilize the system. 2. Press the "HI" fan speed switch to set maximum airflow. 3. Put the temperature control switch in maximum cooling position. 4. Press the "Internal Air Circulation" switch. 5. Compare the flow of bubbles in the sight glass of receiver dryer with the drawings in the following table. IMPORTANT Overfilling refrigerant can cause dangerous high-pressure and poor cooling action. Low refrigerant level can cause compressor damage. Always maintain refrigerant at normal level.
Inspection, Maintenance and Adjustment 4-63 DX225LC-3 Amount of Refrigerant Appearance of the Sight Glass Solutions Normal Almost clear. All bubbles disappear. High No bubbles are seen. Charge or withdraw the system with the correct amount of HFC-134a refrigerant. Low A flow of bubbles is visible.