2,000 HOUR / YEARLY SERVICE Perform All Daily, 50, 250, 500 and 1,000 Hour Service Checks Replace Outer and Inner Air Cleaner Filters WARNING 2 AVOID DEATH OR SERIOUS INJURY Never clean or attempt to remove air cleaner filter if the engine is running. 1 Figure 102 FG019434 NOTE: Replace outer element after cleaning 5 times or every 2,000 hours of service. NOTE: Replace inner element whenever a new outer element is installed. 1. Open the side door of the machine, remove 6 hooks (2, Figure 102), then remove cover. 2 2. Remove evacuator valve (1, Figure 103) from the air cleaner cover (2). NOTE: Inspect evacuator valve seal lips for wear or damage. Replace valve if necessary.
Install evacuator valve with lips parallel to the cover. 1 4 3. Hold the outer element (4, Figure 103), rock it lightly up and downward, and swing the element to pull it out. Remove inner element (5) after doing this. Figure 103 FG000425 4. Wipe off the dirt stuck to the air cleaner cover and the inside of the air cleaner housing. NOTE: When replacing the outer element, replace the inner element simultaneously. Do not reuse the inner element. NOTE: If the inner element is not installed properly and the outer element and cover are installed, the outer element will be damaged. 5. Remove inner element (5, Figure 104), then install a new inner element.
Insert the inner element properly so it does not move. 6. Push the new outer element (5, Figure 104) in straight to the air cleaner body. 4 5 FG000426 Figure 104 DX225LC-3 Inspection, Maintenance and Adjustment 4-66