Doosan DX225LC-3 — Table of Standards for Allowed Tap Water

DX225LC-3 Inspection, Maintenance and Adjustment 4-94 Antifreeze Concentration Tables Ethylene Glycol - DOOSAN Genuine Antifreeze Solution (for all seasons) (2,000 Hour/1 Year) Ambient Temperature Cooling Water Antifreeze -20°C (-4°F) 67% 33% -25°C (-13°F) 60% 40% -30°C (-22°F) 56% 44% -40°C (-40°F) 50% 50% NOTE: The concentration shall be kept at 50% and in worst case at 30% minimum for the least corrosion resistance. NOTE: Replacement cycle of the DOOSAN Genuine Product is 2,000 hours or one year.

Table of Standards for Allowed Tap Water Requirement Item Inorganic chloride Sulfates Total Hardness Total Solids Acidity Value 5.5 - 9.0 PPM (Parts Per Million) - Unit of concentration of minor materials. • 1 ppm = 1 mg/1 kg, 1 mL/1 L ° d.H - Unit of concentration of minor materials. • 1° d.H = 17 ppm CAUTION AVOID INJURY The standard of tap water is for referece only, and may not be regarded as a standard. If quality of the water is not trustable, stop using tap water whenever possible and use distilled water.