Doosan DX225LC-3 — Hydraulic Cylinders

VENTING AND PRIMING HYDRAULIC SYSTEM Main System Pump NOTE: If pump is run without sufficient oil in the main hydraulic pump, damage can occur. Always vent pump of air after draining hydraulic system. 1. With the engine stopped, remove vent plug (Figure 166) to see if any oil is present. 2. If oil is not present, fill pump with oil through port (Figure 166). 3. Install vent plug (Figure 166) first. Figure 166 FG020084 4. Start engine and run it for several minutes at "LOW IDLE". This will pressurize the hydraulic oil tank and system. 5. Slowly loosen vent plug (Figure 166) several turns, until hydraulic oil flows out of plug. This shows that air has been released. 6.

Tighten the plug (Figure 166). Hydraulic Cylinders IMPORTANT If cylinders are operated in "HIGH IDLE" after the hydraulic system has been drained or the cylinder has been rebuilt, damage to piston packing and seals can occur. Always vent air from cylinders at "LOW IDLE" and at a slow speed. 1. Run engine at "LOW IDLE". Extend and retract each cylinder to within 100 mm (4 in) of fully stroking it 4 - 5 times. 2. Operate fully extend and retract each cylinder 3- 4 times. 3. Repeat procedure until cylinders extend and retract smoothly. DX225LC-3 Inspection, Maintenance and Adjustment 4-102