Counterweight O I WARNING AVOID DEATH OR SERIOUS INJURY Death or serious injury can occur from a counterweight falling during removal or installation. Do not allow personnel under or around the counterweight during removal or installation. WARNING when performing inspection DO NOT OPERATE Use certified cables and shackles of adequate load rating. Improper lifting can allow the load to shift and cause death or serious injury. 190-00695A or maintenance ON OFF Figure 2 FG018470 Removal 1. Park on firm and level ground. 2. Lower front attachment (bucket) to ground. 1 3. Stop engine. 5 4. Move safety lever to "UNLOCK" position. 5. Turn starter switch to "I" (ON) position.

WARNING AVOID DEATH OR SERIOUS INJURY If engine must be running while performing maintenance, use extreme care. Always have one person in the cabin at all times. Never leave the cabin with the engine running. 4 3 6. Fully stroke work levers (joysticks) in all directions to relieve any pressure from accumulators. 7. Move safety lever to "LOCK" position. FG020092 2 8. Turn key to "O" (OFF) position and remove from starter switch. Figure 3 9. Attach maintenance warning tag on controls. 10. Turn battery disconnect switch to "OFF" position. 11. Make sure all electrical lines and other items are disconnected. 12.

Using a suitable lifting device capable of handling a heavy load, partially support counterweight (1, Figure 3) before loosening four bolts (2, Figure 3). Stop lifting with assist crane as soon as lifting slings are taut. 13. Remove four bolts (2, Figure 3) and washers (3) from counterweight (1, Figure 3). NOTE: Heat bolts, if necessary, to free them. DX225LC-3 Transportation 5-2