14. When bolts (2, Figure 3) and washers (3) have been removed, lift counterweight (1) a very short distance above support frame (4) and stop. Check slings and make sure counterweight is being supported evenly. Installation 1. Using suitable lifting device capable of handling the weight of the counterweight. Raise counterweight (1, Figure 4) into position just above support frame (4) leaving counterweight suspended. Verify that counterweight is level and even. 5 1 NOTE: Leave counterweight (1, Figure 4) suspended 3 mm (0.125") above support frame (4) until all four mounting bolts (2) are started in counterweight mounting holes. 2. Slide washers (3, Figure 4) onto bolts (2).
Apply Loctite #242 to mounting bolt threads. 3. Install four bolts (2, Figure 4) with washers (3) into counterweight until washers contact support frame. Fully lower counterweight onto support frame and finish tightening bolts. 4 NOTE: Torque bolts (2, Figure 4 ) to values shown in the following table. 3 2 FG020092 Figure 4 4. Remove lifting device and lifting eyes from counterweight lifting holes. (5, Figure 4) 5. Make sure all electrical lines and other items are connected. 6. Turn battery disconnect switch to "ON" position. Transportation 5-3 DX225LC-3 Model Bolt Torque DX225LC-3 150 kg•m (1,085 ft lb)