Doosan DX225LC-3 — Engine

DX225LC-3 Troubleshooting 6-2 Problem Cause Correction Work mode (Power mode or Economy mode) selector does not work. Blown fuse. Replace fuse. Work mode selector switch failed. Replace switch. Connector failed. Replace connector. Wiring harness damaged. Repair or replace as required. EPOS controller failed. Repair or replace as required. Working mode selector does not work. Blown fuse. Replace fuse. Working mode selector switch. Replace switch failed. Connector failed. Replace connector. Wiring harness damaged. Repair or replace as required. EPOS controller failed. Repair or replace as required. ENGINE Problem Cause Correction Starter does not operate. Low battery power. Charge battery.

Poor terminal contact. Clean and tighten connections. Starter switch failed. Replace switch. Starter relay failed. Replace relay. Starter controller failed. Replace controller. Wiring harness faulty. Replace harness. Battery relay failed. Replace relay. Blown fuse. Replace fuse. Starter engages, engine does not start. Fuel gelled in cold weather. Replace fuel. Fuel filters plugged. Replace filters. Water or dirt in fuel system. Clean system and add new fuel. Air in fuel system. Purge air from system. Engine stop control failed. Contact your DOOSAN dealer. Engine stop relay failed. Replace relay. Blown fuse. Replace fuse. Engine starts, runs only at low speed or shuts down.

Engine oil viscosity incorrect. Change oil. Clogged or dirty fuel injectors. Clean injectors. Fuel filters plugged. Replace filters.