Point Opreations [Point 1 I Inspection: Inspect the switches. Neutral switch: Normal if turned OFF when depressed. Backup lamp switch: Normal if turned ON when depressed. [Point 21 Adjustment: Adjust the shift lever operating force. Set a spring scale at the shift lever rod instal - lation hole and measure the operating force. Adjust the operating force to the standard level by turning the adjusting bolt. Shift lever operating force: 34.3 - 53.9 N (3.5 - 5.5 kg) [7.7 - 12.1 Ibl Reassembly: Install the steel ball in the correct position. [Point 41 Reassembly: Place the steel ball in the detent hole, coat grease on the detent spring and paste it on the lock ball. Reassembly:
Coat grease on the steel ball (safety valve) and paste it to stand on the safety valve contact face of the upper cover. I [Point 51 Disassembly: Use the service bolt to extract the selector valve stopper. Service bolt size: M6 x 1.0