Toyota — Engine

AIR CLEANER CLEANING.INSPECTION 1. Open the engine hood. 2. Remove the element. (1) Element Note: In case of the double element type (OPT), do not remove the inner element for other than replacement. L I 3. Clean the element. (1) For ordinary cleaning, blow with compressed air [ I 0 0 psil or less] vertically along the pleats from the inside of the element. If heavily contaminated, washing is possible. (2) Element washing method Dissolve neutral detergent in tepid water [690 kPa (7kg/cm 2 ) (approx. (104OF)) and immerse the element in it for about 3 0 minutes. Then, rinse the element well with clear water. [Water pressure:

2 7 5 40°C kPa (2.8 k g /cm 2 ) less1 After washing, naturally dry the element or dry the element with a dryer (cold air). 140 psil or Note: Do not damage the element during washing. Never use compressed air or hot air for drying. 4. Clean the evacuator valve (dust discharge valve). (1) Hold the tip end of the evacuator valve and discharge dust and dirt from the inside of the valve. 5. Inspect the element. (1) After cleaning, place an electric bulb in the element t o inspect any damage in the element. If any pin - hole, tear or damage is found, replace it with a new element. 6. Element replacement Replace the element after it is washed six times or generally at intervals of 1 2 months.