CLOGGING WARNING SYSTEM INSPECTION 1. Warning lamp inspection (1 See that the air cleaner warning lamp comes on when the ignition switch is turned ON and goes out when the engine starts. 2. Individual inspection (1) Use a mity vac to apply a negative pressure to the vacuum switch, and inspect conduction. Standard Gasoline models: 2942 mmAq) (22.1 f 294 Pa (300 f 30 mmHg): Conduction Diesel models: 7473 f 2.2 + 5 8 mmAq) (56.0 f 569 Pa (762 + 4.3 mmHg): Conduction