LUBRICATION SYSTEM 2. Disassembling, inspecting and reassembling lubrication system 2.1 Inspecting oil pump 2.1.1 Measuring clearance between oil pump housing inside diameter and oil pump outer gear outside diameter Measure the clearance using thickness gauges. Replace the gear or housing if the limit is exceeded. Measuring clearance between oil pump housing inside diameter and oil pump outer gear outside diameter 2.1.2 Measuring the end clearance between oil pump outer gear width and oil pump hous- ing depth Measure the end clearance using feeler gauges. Replace the gear or housing if the limit is exceeded.
Measuring the difference between oil pump outer gear width and oil pump housing 9-5 Item Standard Limit 0.100 to 0.196 mm [0.0039 to 0.0077 in.] Item Standard Limit End clearance between oil pump outergear width and oil pump housing depth 0.040 to 0.100 mm [0.0016 to 0.0039 in] 0.25 mm [0.0099 in]