Mitsubishi — 2.5.1 Checking water pump for smooth rotation

COOLING SYSTEM 2.3 Reassembling thermostat 8 to 10 N 㨯 m {0.8 to 1.0 kgf 㨯 m} [5.8 to 7.2 lbf 㨯 ft] Reassembling thermostat 2.4 Inspecting thermoswitch &$87,21 Both water and the thermoswitch become hot. Pay attention to prevent burn and fire. Immerse the temperature-senser in oil and measure the resistance while raising the oil temperature. If the resistance extremely deviates from the standard, replace the thermoswitch. 120°C [248°F] 30 m Ω Inspecting thermostat 2.5 Inspecting water pump 2.5.1 Checking water pump for smooth rotation Check to make sure that the impeller and shaft of water pump rotate smoothly without noise and irregularities. If faulty, replace the water pump assembly.

Checking impeller and shaft for smooth rotation 10-4 Temperature Standard