ELECTRICAL SYSTEM 1.2 Inspection before removing alternator (A007TA0171B (12V-40A), A007TA8271A (24V-25A)) 1.2.1 Inspecting alternator operation Locate the cause of faulty charging from malfunctions described below. Do not remove the alternator for inspection and repair unless inspection cannot be performed with the alternator installed on the engine. 1.2.2 Handling precaution Improper handling could cause damage or failure to the alternator. (1) Connect battery cables correctly. B terminal is positive (+), and E terminal is negative (-). (2) Do not use any high voltage tester such as megger. (3) Do not disconnect lead wire from B terminal of the alternator while the engine is running.
(4) Battery voltage is constantly applied to B terminal of the alternator. Do not ground at this terminal. (5) Do not short circuit or ground at L terminal. (For a built-in IC regulator type) (6) When a steam cleaner is used, do not allow the steam directly contact the alternator. 12-4 Overcharge Adjusted value of voltage regulator is high. Faulty battery. Over dis- charge Low adjusted value of voltage relay. Faulty alternator output. Electric power consumption is extremely high. Special load is used. Faulty wiring.